Surveillance System Brands Notes
Amcrest
OEM: incomplete
Network
Scan:
- Amcrest Technologies
MAC(s):
- 9c:8e:cd
RTSP
Channel:
- Channel 1 = "1"
- Channel 2 = "2"...
Identifier:
- Sub Stream = "1"
- Main Stream = "0"
URL: /cam/realmonitor?channel=$CHANNEL&subtype=$IDENTIFIER
- ie., Sub Stream = rtsp://admin:admin@192.168.1.200:554/cam/realmonitor?channel=1&subtype=1
Notes
Notes:
- The Amcrest that is in the api Manufacturers tab will work for a NVR and stand alone camera(s) if needed.
- I created the Manufacturer to automatically set it to the Sub Stream, so essentially the Identifier you put in the api shouldn't matter.
Location Examples:
- Marcos Pizza - 1271 Cincinnati (NVR and cameras)
- Marcos Pizza - 2003 Hampton (standalone camera "Cut Table")
Arecont Vision
OEM: incomplete
Network
Scan:
- Arecont Vision
MAC(s):
- 00:1a:07
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete - h264.sdp<channel>?res=(half|full)&x0=(0..1600)&y0=(0..1200)&x1=(32..1600)&y1=(32..1200)&qp=(16..36)&ssn=(1..65535)&[bitrate=(0..65536)]&[fps=1..100]
- ie., Sub Stream =
Notes
Notes:
- No other data on this one yet.
Location Examples:
- incomplete
Axis
OEM: incomplete
Network
Scan:
- Axis Communications AB
MAC(s):
- ac:cc:8e
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
Blue HD
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
Bosch
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
CamHi Pro
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
Cortex
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
DMSS
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
Hanwha Techwin
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
Hikvision
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
Lorex
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
LTS
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
Lux Pro
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
Night Owl
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
Reolink
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
Swann
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
Turing Video
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
TVT CO
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete
Vivotek
OEM: incomplete
Network
Scan:
- Vivotek, Inc.
MAC(s):
- 00:02:d1
RTSP
Channel:
- N/A (both Manufacturers are built for stand alone cameras so the channel is irrelevant)
Identifier:
- N/A (both Manufacturers are built for Sub Stream regardless of what we put in for the "identifier")
URL: /live1s2.sdp (non-fisheye cameras) "Vivotek Standalone Camera"
- ie., Sub Stream = rtsp://SAVI:%400Savi23@192.168.5.155:554/live1s2.sdp
/live2.sdp (fisheye cameras) "Vivotek Standalone Fisheye"
- ie., Sub Stream = rtsp://SAVI:%400Savi23@192.168.5.110:554/live2.sdp
Notes
Notes:
- Only dealt with stand alone cameras up to this point.
- No information on NVR's.
- The default password I've found so far is: root:<empty>.
- I've added Vivotek cameras to a UNV NVR without logging into the camera itself. For the user, use "root", and keep the password at what is auto-filled.
- Also read the port 5556 is the "video" port to exclude audio I'm assuming, however, haven't tested it yet.
Location Examples:
- Wolf Den - Wapato
Brand Template
OEM: incomplete
Network
Scan:
- incomplete
MAC(s):
- incomplete
RTSP
Channel:
- incomplete
Identifier:
- incomplete
URL: incomplete
- ie., Sub Stream =
Notes
Notes:
- incomplete
Location Examples:
- incomplete