CRORZAR MOTION SETTINGS
There are 3 DIP switches located just left of the battery. For normal operation they should all be to the far left. If the customer is having false alarms we can set the top switch to the right, this will make it so someone has to cross 2 zones instead of one before it will go off. Far fewer false alarms but it is not ideal in close spaces where someone wouldn’t have to walk across the motions path very far like a hallway.
The middle DIP switch should AWLAYS be to the left. This gives the motion 3 minutes inbetween sending a motion signal. WAY better battery life. If the switch is to the right we will only get a couple months of battery life in a commercial space.
The bottom DIP switch is the LED. Left it is on, right it is off.